Power supply |
12-24 Volt DC (+/- 5%)
Consumption at 12 V ~200 mA + output current
Consumption at 24 V ~120 mA + output current
|
I/O interface |
Input 1 – Trig input, starts
sampling
Input 2 – Cal. input, cal mode active
Input 3 – Reset input, resets outputs
Input 4 – Halt, interrupts sampling
|
Output 1 Stop Error,
major errors
Output 2 Time Error, pass time errors
Output 3 Layer Error, missing layer
Output 4 Paper present, length detect |
Paper opacity |
From 20 g/m2 up to 1000 g/m2
white cardboard.
Coloured sheets up to 120 g/m2.
Folded sheets up to 7 layers depending on
colour (opacity). |
Pass time |
Minimum calibration time required
= 47 ms
Minimum detection time required = 23 - 47
ms |
Distance |
Distance between paper sheets
in a flow, min 10 ms. |
Output configuration |
PNP |
Active at Up residual voltage (1
V)
150 mA at Up = 12 V
250 mA at Up = 24 V |
NPN |
Active at 0 V + residual voltage (1 V)
250 mA/max Up |
Serial interface |
RS485/RS422 |
Additional configuration settings
(DIP) |
- Sampling length (20 ms or entire sheet).
- Trig selection (auto edge trig or external
trig by Input 1)
- Trig duration (short or long trig signal
duration)
- Error output duration (15 ms pulse or
held until reset)
- Output signalling (signal for group
of errors or for specific error)
- Interface selection (I/O or serial communication
+ I/O)
- Signal configuration (PNP/NPN)
- Detection accuracy (High – Medium
|
EMC compliance |
EN50081-2 and EN50082-2 |